TM 9-2350-260-20-1-3
BILGE PUMP RELAY ENCLOSURE ASSEMBLY REPAIR (Sheet 9 of 12)
Solenoid Relay Replacement (Sheet 2 of 5)
3.
Using 7/16 inch socket, remove screw (F) with two
flat washers.
4.
Using 7/16 inch socket, remove nut (G) with
lockwasher.
Throw lockwasher away.
5.
Remove bus bar (H).
6.
Using 7/16 inch socket, remove nut (J) with
lockwasher.
Throw lockwasher away.
7.
Remove lead 451 from terminal A2.
8.
Using 5/16 inch socket, remove nut (K) with
lockwasher and flat washer.
Throw lockwasher
away.
9.
Remove ground lead (L) from terminal X2.
10. Using 5/16 inch socket, remove nut (M) with
lockwasher and flat washer.
Throw lockwasher
away.
11. Remove lead 451 from terminal X1.
12. Using screwdriver, remove two screws (N) with
lockwashers.
Throw lockwashers away.
Go on to Sheet 3
TA147232
10-200