BILGE PUMP RELAY ENCLOSURE ASSEMBLY REPLACEMENT (Sheet 2 of 2)
INSTALLATION:
1.
Place four external tooth lockwashers (A) over screw
holes on mounting bracket.
2.
Place relay (B) over external tooth lockwashers (A).
3.
Insert four screws and new lockwashers by hand to
aline relay (B) with bracket.
4.
Using wrench, tighten screw (D) below connector
relay (B).
5.
Using socket, tighten other three screws (C).
6.
Conned electrical connector (E).
Using spanner
wrench, tighten.
7.
Connect three battery ground straps (page 10-294).
8.
Close
turret
platform
access
door
(TM 9-2350-260-10).
End of Task
TA147223
10-191