TM 9-2350-260-20-1-3
BILGE PUMP RELAY ENCLOSURE ASSEMBLY REPAIR (Sheet 1 of 12)
PROCEDURE INDEX
PROCEDURE
PAGE
Circuit Breaker Replacement
10-192
Cable Assembly Replacement
10-195
Solenoid Relay Replacement
10-199
Circuit Breaker Replacement (Sheet 1 of 3)
TOOLS:
Cross-tip screwdriver (Phillips)
7/16 in. socket with 1/2 in. drive
Ratchet with 1/2 in. drive
5 in. extension with 1/2 in. drive
SUPPLIES:
Crocus cloth (Item 14, Appendix D)
Steel wool (Item 55, Appendix D)
Gasket(10951769)
Lockwasher (MS35338-43) (6 required)
Lockwasher (MS35333-39) (2 required)
Lockwasher (MS35338-101) (2 required)
PRELIMINARY PROCEDURE:
Remove enclosure assembly from tank (page 10-190)
REMOVAL:
1.
Using screwdriver, remove four screws (A) and
lockwashers (B).
Throw lockwashers (B) away.
2.
Remove cover (C) and gasket (D) from enclosure
assembly (E).
Throw gasket (D) away.
Go on to Sheet 2
TA147224
10-192