TM 9-2350-260-20-1-3
RELAY AND CIRCUIT BREAKER MOUNTING PLATE REPLACEMENT (Sheet 1 of 2)
TOOLS: 9/16 in. socket with 1/2 in. drive
REFERENCE: TM 9-2350-260-10
PRELIMINARY PROCEDURES:Remove air cleaner blower motor relay (page 10-184)
Remove two circuit breakers (page 10-186)
Remove fire extinguisher relay (page 10-181)
REMOVAL:
1.
Using 9/16 inch wrench, remove two screws (A) at rear end of plate (B).
2.
Using 9/16 inch wrench, loosen two screws (C) at front end of plate (B).
3.
Slide plate (B) to rear and remove it.
Go on to Sheet 2
TA174220
10-188