TM-9-2350-260-20-1-3

TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 3 OF 4 CHAPTERS 10 THRU 15

  TM-9-2350-260-20-1-3 - Page 214 of 783

TM 9-2350-260-20-1-3
BILGE PUMP RELAY ENCLOSURE ASSEMBLY REPAIR (Sheet 11 of 12)
Solenoid Relay Replacement (Sheet 4 of 5)
4.
Place ground lead (E) with flat washer into position
on X2 terminal.
5.
Using 5/16 inch socket install nut (F) with new
lockwasher.
6.
Place lead 451 with flat washer into position on
terminal X1.
7.
Using 5/16 inch socket, install nut (G) with new
lockwasher.
8.
Place lead 451B with flat washer into position on
terminal A2.
9.
Using 7/16 inch socket, install nut (H) with new
lockwasher.
10. Place two flat washers at position (J) on circuit
breaker and one flat washer at position (K) of relay.
11. Position bus bar (L) over flat washers at (J) and (K ).
12. Using 7/16 inch socket, install screw and two flat
washers (J) through bus bar on circuit breaker at
position (J).
13. Using 7/16 inch socket, install nut and flat washer to
hold bus bar at position (K).
TA147234
Go on to Sheet 5
10-202


Back to Top