TM 9-2350-260-20-1-3
BULKHEAD RECEPTACLE MOUNTING PLATE REPLACEMENT (Sheet 2 of 3)
2.
Using screwdriver, remove four screws and washers
securing each of five cable connectors (B).
NOTE
Identify and tag each cable connector
as you remove them.
3.
Remove cable connectors (B) and then gaskets.
Throw gasket away.
4.
Using 9/16 inch socket, remove seven screws and
washers (C) securing plate (D).
5.
Remove plate (D) and gasket (E).
Throw gasket
away.
Go on to Sheet 3
TA147242
10-210