TM-9-2350-260-20-1-3

TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 3 OF 4 CHAPTERS 10 THRU 15

  TM-9-2350-260-20-1-3 - Page 170 of 783

TM 9-2350-260-20-1-3
INSTRUMENT PANEL CLUSTER ASSEMBLY REPAIR (Sheet 19 of 23)
Instrument Panel Wiring Harness Replacement (Sheet 1 of 4)
PROCEDURE INDEX
PROCEDURE
PAGE
Removal
10-158
Installation
10-160
TOOLS:
Pliers, slip joint
3/8 in.
combination box and open end wrench
Flat-t screwdriver
SUPPLIES:
Silicone compound (Item 32, Appendix D)
Lockwasher (MS35338-42) (4 required)
PRELIMINARY PROCEDURE:
Remove instrument panel from tank (page 10-136)
REMOVAL:
1.
Using screwdriver, remove four screws and
lockwashers (A) securing receptacle connector (B)
to panel.
Throw lockwashers away.
2.
Using wrench, remove nut and flat washers (C),
securing harness junction (D) to panel.
3.
Disconnect two leads (circuit 27 and 36) from engine
oil pressure gage (E) by pulling out
Go on to Sheet 2
TA147190
10-158