TM 9-2350-260-20-1-3
BATTERY TESTING AND REPLACEMENT (Sheet 5 of 13)
10. Readings between cells of any one battery must be within 0.025 of each other.
If they are not, replace battery.
REMOVAL:
1.
Locate three battery ground cable terminals (A).
2.
Using 1/2 inch box wrench on nut (B) and 1/2 inch
open end wrench on bolt (C), loosen nut (B) and bolt
(C) on three battery ground cable terminals (A).
CAUTION
As each cable is removed, cover
battery ground cable with rags and
position cable to prevent contact with
battery box or batteries to prevent
arcing.
3.
Using battery terminal puller, move three battery
ground terminals (A) from at post (D).
Lay terminals
and cables aside.
Go on to Sheet 6
TA147336
10-304