B3Y
1. Lowertrimvane(seeyour-10)
.
2.
Open power plant front access door (see your -10).
3.
Remove right headlight wiring harness plug (1) from front
main harness jack (2) at bulkhead.
4.
Measure voltage between front main harness jack (2) pin F (low
beam) (3) or pin E (high beam) (4) and ground.
5.
Does multimeter read less than 17 volts?
B4Y
1.
Install right headlight wiring harness circuit 514 or 515
plug on IR head light.
2.
Faulty front main wiring harness. Beyond unit
maintenance repair.
3.
Notify your supervisor.
003200-6
B3YN
1.
Repair faulty right headlight
wiring harness circuit 514/515
(WP 0312 00).
2.
Verify no faults found.
INFRARED HEADLIGHT(S) DOES NOT OPERATE — Continued
0032 00
TM 9-2350-261-20-1