TM 9-2350-261-20-2
REPAIR WIRING HARNESS — Continued
0312 00
5.
If removed, install Y-type adapters and dummy plugs.
a.
Install Y-type adapter (3) on harness leads (4).
b.
Install dummy plugs (5) in male or female connector (6).
FOLLOW-THROUGH STEPS
1.
Use multimeter to perform continuity check before connecting batteries.
2.
Connect battery ground lead (WP 0294 00).
END OF TASK
0312 00-6