TM-9-2350-261-20-2

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 2 OF 4

  TM-9-2350-261-20-2 - Page 527 of 1008

TM 9-2350-261-20-2
REPAIR RECEPTACLE
0313 00
THIS WORK PACKAGE COVERS:
Disassembly
( page 03 13 00 -1 ).
Clean, Inspect, and Repair (page 0313 00-2).
Assembly
( p ag e 0 313 0 0 -2 ).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
Digital Multimeter (WP 0780 00, Item 43)
Electrical Tool Kit (WP 0780 00, Item 80)
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Soldering Gun (WP 0780 00, Item 33)
Materials/Parts
Insulation sleeving (WP 0782 00, Item 30)
Insulation sleeving (WP 0782 00, Item 31)
Insulation sleeving (WP 0782 00, Item 32)
Insulation sleeving (WP 0782 00, Item 33)
Insulation sleeving (WP 0782 00, Item 34)
Solder (WP 0782 00, Item 71)
Personnel Required
Unit Mechanic
Equipment Condition
Engine stopped/shutdown (see your -10)
Battery ground lead disconnected (WP 0294 00)
Carrier blocked (see your -10)
DISASSEMBLY
NOTE
Use same procedure for repairing single or multiple lead, and male or female receptacle.
1.
Loosen nut (1) from receptacle (2). Slide nut back on leads (3).
2.
Remove grommet (4) with contacts (5) from rear of receptacle.
3.
Push leads (3) into grommet (4) until contacts (5) are fully exposed on other side of grommet. Remove grommet and
nut (1) from leads.
4.
Clip or desolder leads from contacts. Use soldering gun. Discard contacts.
031300-1


Back to Top