TM 9-2350-261-20-3
REPLACE 4.2 KW GENERATOR SET ENCLOSURE (M577A2 ONLY) — Continued
0472 00
INSTALLATION
1.
Install enclosure (7). Use lifting device and sling.
2.
Install four clamps (11), washers (10), and thumbscrews (9) in generator set enclosure (7). Secure with four new cotter
pins (8).
3.
Place enclosure (7) on bulkhead. Secure with four washers (6) and screws (5). TIGHTEN SCREWS TO 55-60 LB-FT
(75-81 N·M) TORQUE. Use torque wrench.
4.
If needed, add washers (4) to remove play between enclosure (7) and hull lugs.
5.
Align enclosure (7) with two hull lugs. Secure with two washers (4), washers (3), screws (2), and new locknuts (1).
FOLLOW-THROUGH STEPS
1 .
In stall 4.2
KW
g enerator s et (M57 7A2 o nly ) (see you r -1 0).
END OF TASK
0472 00-2