TM 9-2350-261-20-4
REPLACE ELECTRONIC EQUIPMENT HEATER CONTROL BOX-TO-FUEL
PUMP LEAD (M577A2 ONLY) — Continued
0632 00
INSTALLATION
1.
Install two clamps (1) and five clamps (2) on circuit 402A lead (3).
2.
Place two clamps (1) on two floor weldnuts. Secure with two screws (4).
3.
Place lead (3) in six cradles on rear bulkhead. Secure with six clips (5).
4.
Place lead (3) in ten cradles on compartment roof. Secure with ten clips (6).
5.
Place five clamps (2) on forward bulkhead weldnuts. Secure with five screws (7).
6.
Connect lead (3) to fuel pump lead (8).
7.
Connect lead (3) to wiring harness lead (9).
063200-3