REPAIR FLAME DETECTOR SWITCH — Continued
0637 00
ASSEMBLY
1.
Carefullyinsertceramicrod(12)intohousing(5)
.
2.
Install bow spring (11) in mount (4).
3.
Install switch (10) in mount (4) and housing (5). Be sure ceramic rod (12) fits into extension on switch.
4.
Install switch (10) on mount (4) and housing (5). Secure with two screws (9), washers (8), washers (7), and nuts (6). Do
not tighten.
063700-3