TM 9-2350-261-34
REPAIR RADIATOR AUXILIARY TANK — Continued
0026 00
NOTE
Therearetwowaystopressuretesttank
.Ifusingwaterpressure
,doStep3,thengotoStep5
.
Ifusingairpressure
,gotoStep4.
3.
Apply internal water pressure of 18-20 psi for minimum of 3 minutes. Check for water leaks.
4.
Submerge tank (1) in water and apply pressure of 18-20 psi for minimum of 3 minutes. Check for air leaks.
NOTE
Mark areas of leaks and remove all plugs before welding.
5.
Weld areas of leaks in accordance with TC 9-237. Use electrode type 5356. All weld sizes to be minimum requirement
for leak repair.
6.
RepeatStep3orStep4afterwelding.
7.
Refinish tank (1). Treat per class 1A, specification MIL-C-5541E, see TM 43-0139.
FOLLOW-THROUGH STEPS
1.
Install radiator auxiliary tank (see your -20).
END OF TASK
0026 00-2