TM 9-2350-261-34
REPLACE FRONT MAIN WIRING HARNESS — Continued
0032 00
17. Remove eight nuts (1), washers (2), and screws (3). Separate master switch panel assembly (4) from distribution box (5).
18. Remove circuit 2A lead (13) or (19) and circuit 2 lead (16) or (18) from master switch panel assembly (see your -20).
NOTE
The distribution boxes shown below are M113A2 configuration. Your distribution box may
have leads not shown here. Remove and install those leads as needed to do Steps 19 - 22 below.
19. Remove screw (6), lockwasher (7), and circuit 6 lead (8) from bus bar (9). Remove circuit 6 lead and grommet (10) from
distribution box (5). Discard grommet and lockwasher.
20. On 100 amp generator system, remove screw (11), lockwasher (12), and circuit 3 lead (13) from circuit breaker (14).
Remove circuit 3 lead and grommet (15) from distribution box (5). Discard grommet and lockwasher.
21. On 100 amp generator system, remove circuit 2 lead (16) from master switch panel assembly (see your -20). Remove
circuit 2 lead and grommet (17) from distribution box (5). Discardgrommet
.
22. On 200 amp generator system, remove circuit 2 lead (18) and circuit 2A lead (19) from master switch panel assembly
(see your -20). Remove circuit 2 lead, circuit 2A lead, and two grommets (20) and (21) from distribution box (5).
Discard grommets.
0032 00-4