INSTALL PERSONNEL HEATER KIT (M1064 ONLY) — Continued
52. Secure circuit 402 lead (6) to four weldnuts (11) with four clamps (12) and screws (13).
53. Remove screw (15) and two washers (20) securing clamp (16) and dome light lead (17) from weldnut (18).
54. Secure heater wiring harness (1), ground lead (19), clamp (16), and dome light lead (17) to weldnut (18) with screw
(15) and two washers (20).
FOLLOW-THROUGH STEPS
1.
Open fuel shutoff cock (see your -10) and check for leaks.
2.
Connect battery ground lead (see your -20).
3.
Start personnel heater (see your -10) and check personnel heater installations for proper operation and leaks.
4.
Turn personnel heater OFF (see your -10).
5.
Install floor plates (see your -20).
6
.
Raise and lo ck ram p (see yo ur -10).
7
.
Stop eng ine (see yo ur -10).
END OF TASK
0056 00-11