TM-9-2350-261-34

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

  TM-9-2350-261-34 - Page 407 of 785

TM 9-2350-261-34
REPAIR AUXILIARY POWER UNIT COVER (4.2 KW GENERATOR SET
ONLY) (M577A2 ONLY) — Continued
0057 00
8.
Check eyelets, washers, and studs. Replace parts that are bent, broken, or missing.
REPAIR OR REPLACEMENT
NOTE
The materials used to make a cement patch are adhesive, round patch of vinyl coated nylon
cloth, roller, board, wire brush, and soft bristle brush.
1.
Select patch that overlaps damaged area with a margin of at least 3/4 inch (19 mm) on all sides.
2.
Place board under damaged area for a flat working surface.
3.
Buff patch and damaged area of fabric with wire brush.
WARNING
Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These
compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you
dizzy and irritate your eyes and throat.
Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes.
Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves.
0057 00-2


Back to Top