INSTALL PERSONNEL HEATER KIT (M1064 ONLY) — Continued
0056 00
WARNING
Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These
compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you
dizzy and irritate your eyes and throat.
Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes.
Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves.
37. Apply sealing compound to external threads of nipple (10).
38. Install nipple (10) in personnel heater (1).
39. Install elbow (9) on nipple (10).
40. Install fuel hose (5) to elbows (2) and (9). Secure with sleeves (3) and nuts (4).
41. Secure fuel hose (5) with three clamps (8), lockwashers (7), and screws (6).
0056 00-8