TM 9-2350-261-34
REPAIR POWER CONTROL ENCLOSURE, RIGHT PANEL (M1068 ONLY) — Continued
0083 00
2.
Remove eight screws (5) and lockwashers (6) connecting power supplies (7) to bracket (8) and shift (move or slide)
pow er supplies (7) to the left. Discard lockwashers. Have
h
elper assist.
3.
Remove ten screws (9) and lockwashers (10) from faceplate (11). Lower faceplate. Discard lockwashers.
0083 00-2