REPAIR POWER CONTROL ENCLOSURE, RIGHT PANEL (M1068 ONLY) — Continued
0083 00
2.
Install ground fault interrupter (2) on enclosure (5) with two new lockwashers (4) and screws (3). Install circuit leads
22A, 21A, 3AA, 18C, and 27A (1) on ground fault interrupter (2).
3.
Install connector J29 (1), four screws (2), and new locknuts (3) on enclosure (4). Install circuit lead 34A (5) on J29 (1).
4.
Install connector J28 (6), four screws (7), and new locknuts (8) on enclosure (4). Install circuit lead 44A (9) on J28 (6).
5.
Install connector J27 (10), four screws (11), and new locknuts (16) on enclosure (4). Install circuit leads 11A, 28A,
12A, 28B, and 3W (13) on J27 (10).
6.
Install connector J37 (14), four screws (15), and new locknuts (16) on enclosure (4). Install circuit leads 20B, 18D,
and3AC(17)onJ37(14)
.
7.
Install connector J25 (18), connector J26 (19), two dust caps (20) with retainers, eight screws (21), and new locknuts
(22) on enclosure (4).
8.
Install circuit 32C lead (23), screw (24), and lockwasher (25) on negative terminal of connector J26 (19).
9.
Install circuit 36C lead (26), screw (27), and lockwasher (28) on positive terminal of connector J26 (19).
10. Install circuit 32E lead (29), screw (30), and lockwasher (31) on negative terminal of connector J25 (18).
0083 00-6