TM 9-2350-261-34
REPAIR POWER CONTROL ENCLOSURE, LEFT PANEL (M1068 ONLY) — Continued
0084 00
NOTE
Tag all leads/wires before removal for proper installation later. See wiring diagram (page
0084 00-8) for disassembly/assembly of wires/leads.
5.
Remove six screws (1), lockwashers (2), and eight circuit leads (3) from terminals of relay XK2 socket (4).
6.
Remove two screws (5), locknuts (6), washers (7), and relay XK5 (8) from left panel (9). Discard locknuts.
7.
De-solder/remove four wires (10) from terminals (11) of relay XK5 (8).
8.
Remove two screws (5), locknuts (6), washers (7), and relay XK3 (12) from left panel (9). Discard locknuts.
9.
De-solder/remove five wires (10) from terminals (11) of relay XK3 (12).
008400-3