TM 9-2350-261-34
REPAIR POWER CONTROL ENCLOSURE, LEFT PANEL (M1068 ONLY) — Continued
0084 00
5.
Solder/install four wires (10) on terminals (11) of relay XK4 (13).
6.
Install relay XK4 (13) on left panel (9) and secure with two screws (5), new locknuts (6), and washers (7).
7.
Solder/install five wires (10) on terminals (11) of relay XK3 (12).
8.
Install relay XK3 (12) on left panel (9) and secure with two screws (5), new locknuts (6), and washers (7).
9.
Solder/install four wires (10) on terminals (11) of relay XK5 (8).
10. Install relay XK5 (8) on left panel (9) and secure with two screws (5), new locknuts (6), and washers (7).
0084 00-6