REPAIR POWER CONTROL ENCLOSURE, REAR PANEL (M1068 ONLY) — Continued
10. Install leads 18A and 18B (19) in terminal T2 of reversing contactor RC1 (13).
11. Install leads 17A and 17B (18) in terminal T1 of reversing contactor RC1 (13).
12. Install leads 15A and 15B (17) in terminal 52 of reversing contactor RC1 (13).
13. Install lead 9B (16) in terminal 51 of reversing contactor RC1 (13).
14. Install leads 13A and 13D (15) in terminal L1 of reversing contactor RC1 (13).
15. Install lead 28D (14) in terminal A1 of reversing contactor RC1 (13).
16. Install leads 28G and 28D (14) in terminal L2 of reversing contactor RC1 (13).
17. Install leads 16A and 16B (12) in terminal A2 of reversing contactor RC1 (13).
18. Install contactor relay K1 (2), four screws (8), washers (10), and new locknuts (9) on rear panel (11).
19. Install lead 7A (7) in terminal L1 of contactor relay K1 (2).
20. Install lead 5A (6) in terminal A1 of contactor relay K1 (2).
21. Install lead 2F (5) in terminal A2 of contactor relay K1 (2).
22. Install leads 8A and 8B (4) in terminal L2 of contactor relay K1 (2).
23. Install leads 2C, 2D, and 2F (3) in terminal T2 of contactor relay K1 (2).
24. Install leads 1C and 1D (1) in terminal T1 of contactor relay K1 (2).
0085 00-6
0085 00
TM 9-2350-261-34