TM 9-2350-273-BD
ELECTRICAL SYSTEM
Assessment Steps (Cont'd)
4.
5.
6.
7.
8.
9.
10.
11.
12.
Disconnect turret power cable at turret power relay box, connector 31.
Turn MASTER power switch ON.
Check for power at turret power cable connector.
a. If power is present, go to step 7
0
b. If power is not present, repair turret power cable.
Reconnect turret power cable.
Disconnect turret control wiring harness from connector J3.
Check for power at socket B of connector J3 on the turret relay box.
a. If power is present, go to step 13.
b. If power is not present, go to step 10.
Remove cover of turret power relay box.
Remove wire (CKT 625) from circuit breaker.
Connect this wire to circuit breaker bus bar using existing screw.
6-9