TM-9-2350-277-20-1

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 1 OF 6

  TM-9-2350-277-20-1 - Page 617 of 855

TM 9-2350-277-20-1
COMMANDER’S VISION ENHANCER (DVE) DISPLAY DOES NOT WORK
(M58 ONLY) — Continued
0116 02
2Y
1.
Measure continuity between cable 12461152 connector W3P3 pin
A (1) and connector W3P4 (4) and between connector W3P3 pin
B (1) and ground point (5) on instrument panel.
2.
Does multimeter read 0 ohms?
2YN
1.
Faulty cable 12461152. Replace
cable 12461152 (WP 0866 04).
2.
Verify no faults found.
3Y
1.
Bad commander’s display. Replace commander’sdisplay
.
See TM 9-2350-277-10.
2.
Verify no faults found.
AY
1.
Remove power cable connector W3P3 (1) from connector A1J1
(2) on commander’s display (3). Use a multimeter on connector
W3P3 pin A and pin B (1) to check for voltage.
2.
Is voltage reading less than 18 volts?
AYN
1.
Faulty display. Replace display. See
TM 9-2350-277-10.
2.
Verify no faults found.
011602-2
Change 5


Back to Top