TM 9-2350-277-20-1
HOOK UP/REMOVE MSD/ICE TEST SET TO DCA 6
0117 00
THIS WORK PACKAGE COVERS:
Hook-up (page 0117 00-1).
Removal (page 0117 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
MSD/ICE Test Set (WP 0926 00, Item 61)
Electrical connector pliers (WP 0926 00, Item 31)
Personnel Required
Unit Mech 63T10
Equipment Condition
Engine stopped (TM 9-2350-277-10)
Vehicle blocked (TM 9-2350-277-10)
All external/internal power OFF
HOOK-UP
NOTE
Ensure vehicle engine and all internal/external components are turned off.
1.
Remove MSD (1), ICE Box (8), and two cable assemblies 18876/13608011 (11) and W1 12258784 (5) from transit case.
2.
Connect wiring harness 18876/13608011 (11) connectors P2 (2) and P3 (12) to MSD (1).
3.
Connect wiring harness 18876/13608011 (11) connector P1 (10) to ICE Box (8) jack J6 (9).
4.
Remove cap from DCA 6 jack J2 (3).
5.
Connect wiring harness W1 12258784 (5) connector P1 (6) to ICE Box (8) jack J1 (7).
6.
Connect wiring harness W1 12258784 (5) connector P2 (4) to DCA 6 jack J2 (3).
7.
Power up MSD/ICE, push ICE Box circuit breaker in and press MSD PWR button.
8.
If MSD/ICE fails to power up, notify supervisor.
011700-1
Change 5
(TM 11-7010-256-12&P) M1068A3