MSD/ICE TEST 83 GENERATOR FIELD VOLTAGE
0134 00
THIS WORK PACKAGE COVERS:
Test (page 0134 00-1).
INITIAL SETUP:
Maintenance Level
Unit
Personnel Required
Unit Mech 63T10
References
TM 9-2350-277-10
Equipment Condition
Engine stopped (TM 9-2350-277-10)
Vehicle blocked (TM 9-2350-277-10)
MSD/ICEhookeduptoDCA6(WP011700)
TEST
1.
Select
ICE Testing
from programs menu.
2.
Select button
1. Serial ICE
3.
Select button
1. ICE Tests
NOTE
All M113A3 variants are covered under
M113A3-M1068A3 APC
vehicle selection
4.
Select
M113A3-M1068A3 APC
, then select the
OK
button.
NOTE
Once MSD/ICE hook up screen
OK
button is selected, the MSD/ICE will perform a self test.
If self test fails, notify supervisor.
5.
Select
OK
button on the MSD/ICE hook up screen to proceed.
6.
Select
OK
button after successful self test.
7.
Follow on screen preparation for DCA offsets tests. Select
OK
button.
8.
Use Tab and Shift-Tab to move from one list box to another.
9.
Use spacebar to select/deselect the test.
10. Select
83 Alt/Gen Field Voltage
from
CHARGING SYSTEM
list box. Select
Run Test(s)
button.
11. Start engine and run at 1400-1600 RPM. See TM 9-2350-277-10.
12. Observe MSD display.
a.
If MSD reads
26
to
29.5
(volts), test passes.
b.
If error message appears, see TM 9-6625-2301-14&P.
c.
If reading is erratic or cannot be obtained, go to MSD/ICE test 83 diagnostic troubleshooting (WP 0152 00).
13. Stop engine. See TM 9-2350-277-10.
14. Return to troubleshooting.
0134 00-1/2 blank
Change 5


Back to Top