TM 9-2350-277-20-2
REPAIR AIR CLEANER ASSEMBLY — Continued
0169 01
WARNING
Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These
compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you
dizzy and irritate your eyes and throat.
Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes.
Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves.
4.
Apply a bead of adhesive on the inside flange of the intake (1) (or on the flange of the air cleaner housing).
5.
Insert the intake (1) into the air cleaner housing (2) by pushing it gently by hand until the intake flange (4) contacts the
flange (3) on the air cleaner housing. Wipe off any excess adhesive.
6.
Reaching from the top opening of the air cleaner housing (2), apply a bead of adhesive around the outer edges of the
intake (1) where it contacts the air cleaner housing (2). The bead of adhesive should be approximately 1/4 in. (6 mm)
wide, and it should flow into the joint and adhere to the metal to provide an “airtight seal.”
016901-3
Change 5