TM 9-2350-277-20-2
REPAIR AIR CLEANER RETAINER
0170 00
THIS WORK PACKAGE COVERS:
Removal (page 0170 00-1).
Installation (page 0170 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0926 00, Item 65)
Materials/Parts
Lockwasher (8)
Personnel Required
Mechanic
References
TM 9-2350-277-10
Equipment Condition
Engine stopped (TM 9-2350-277-10)
Carrier blocked (TM 9-2350-277-10)
Power plant access door open (TM 9-2350-277-10)
Air cleaner door removed (TM 9-2350-277-10)
REMOVAL
1.
Release retainer handle (1) and slide out filter element (2).
2.
Remove eight nuts (3), lockwashers (4), and screws (5) from retainer (6) and housing (7). Remove retainer from
housing. Discard lockwashers.
017000-1