TM 9-2350-277-20-2
REPAIR AIR CLEANER RETAINER — Continued
0170 00
INSTALLATION
1.
Position new retainer (6) into housing (7). Secure with eight screws (5), new lockwashers (4), and nuts (3). Tighten
allnutsatthistime
.
NOTE
Check operation of retainer to make sure there is no binding during operation. If binding
occurs, loosen screws and repeat Step 1.
2.
Install filter element (2) and reset retainer handle (1).
FOLLOW-THROUGH STEPS
1.
Install air cleaner door. See TM 9-2350-277-10.
2.
Close power front access door. See TM 9-2350-277-10.
END OF TASK
0170 00-2
Change 5