TM-9-2350-277-20-2

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 2 OF 6

  TM-9-2350-277-20-2 - Page 252 of 783

TM 9-2350-277-20-2
REPAIR AIR CLEANER ASSEMBLY — Continued
0169 01
7.
Open air cleaner element retainer (3) and install air cleaner element (2) into housing.
8.
Install air cleaner door (1) and secure with latch.
9.
Let adhesive dry for eight hours before operating.
FOLLOW-THROUGH STEPS
1.
Install air cleaner (WP 0168 00).
2.
Close power plant access door. See TM 9-2350-277-10.
END OF TASK
0169 01-4
Change 5


Back to Top