42
Semi-
Annual
Power Plant
Bottom Access
Cover, Hull Drain
Plugs, and Final
Drive Drain Plugs
a.
Check final drive drain plugs for leaks.
Tighten leaking plugs (WP 0452 00).
Any Class
III leaks or
missing seals,
covers, or
plugs.
b.
Check for loose or missing hull drain plugs.
If missing, replace hull drain plug. Tighten
loose plugs (WP 0451 00).
c.
Remove power plant bottom access cover
and check for missing or damaged seal.
Replace missing or damaged seal. Install
bottom access cover. TIGHTEN SCREWS
TO 40-50 LB-FT (54-68 N·M) TORQUE.
Use torque wrench (WP 0926 00, Item 79).
Missing or
loose seals,
plugs, or
covers.
d.
Check for loose or missing screws in power
plant bottom access cover. Replace screws
if missing. TIGHTEN LOOSE SCREWS
TO 40-50 LB-FT (54-68 N·M) TORQUE.
Use torque wrench (WP 0926 00, Item 79).