TM 9-2350-277-20-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS — Continued
0155 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
43
Semi-
Annual
Final Drive
a.
Inspect final drive input shaft oil seals for
evidence of leakage. Replace final drive
seals that have leaks (WP 0404 00). Tighten
screws to 21-25 lb-ft (28-34 N·m) torque.
Use torque wrench (WP 0926 00, Item 79).
Any Class III
leaks.
44
Semi-
Annual
Power Plant
Noises
a.
Check power plant operation. If unusual
noises are heard, repair suspect component
or contact higher level of maintenance for
assistance and repair.
45
Semi-
Annual
Exhaust System
NOTE
Carrier leaks exhaust when weather
is cold. For this reason, carbon will
be present around joints and exhaust
pipe connecting clamps. This is normal.
The exhaust system joints will seal
after pipes heat up. Check for exhaust
leaks only after engine reaches normal
operating temperature of 180 -205 F
(71 -93.3 C).
0155 00-79
Change 5