REPLACE POWER CONTROL ENCLOSURE POWER SUPPLIES
(M1068A3 ONLY) — Continued
0090 00
8.
Disconnect jumper cable (2) from power supply connectors (1) and (3).
NOTE
Tag all leads before disconnecting from terminals.
9.
Remove plastic cover (4) from each power supply terminal block (1) and (2).
10. Remove six screws (3) and six leads (5) from both power supply terminal blocks (1) and (2). Reinstall screws and
plastic covers.