TM 9-2350-277-34
REPLACE POWER CONTROL ENCLOSURE POWER SUPPLIES
(M1068A3 ONLY) — Continued
0090 00
11. Remove three screws (4), washers (3), and three leads (2) from power supply (1). Remove power supply from power
control enclosure. Have helper assist.
12. Remove four screws (4), washers (3), and four leads (2) from power supply (5). Remove power supply from power
control enclosure. Have helper assist.
13. Remove four screws (2), lockwashers (3), and bracket (1) from four isolators (5). Discard lockwashers.
14. Remove 16 locknuts (7), screws (4), and four isolators (5) from power conrtol enclosure (6). Discard locknuts.
009000-5
Change 5