TM 9-2350-277-34
NO DC OUTPUT FROM DC POWER SUPPLY (M1068A3 ONLY)
0009 00
INITIAL SETUP:
Maintenance Level
Direct Support
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0120 00, Item 62)
Digital Multimeter (WP 0120 00, Item 38)
Special Purpose P ow er Cable
(WP 0121 00)
Personnel Required
Power-Generation Equipment Repairer 52D10
Helper (H)
References
M1068A3 Wiring Diagram (see your -20)
Equipment Condition
Power control enclosure removed (see your -20)
Power control enclosure faceplate lowered and power
supply cover removed (see your -20)
Unit level troubleshooting completed (see your -20)
WARNING
HIGH VOLTAGE is used in operation of this equipment.
DEATH ON CONTACT may result if personnel fail to observe safety precautions.
NEVER work on equipment unless at least one other person familiar with operation and
hazards of equipment is nearby. That person should also be familiar with giving first aid. When
an operator helps a mechanic, that operator must be warned about dangerous areas.
SHUT OFF POWER supply to equipment before beginning work. Make sure all external
power is OFF/disconnected.
BE CAREFUL not to touch high-voltage connections when installing or operating this
equipment.
000900-1
Change 4