NO DC OUTPUT FROM DC POWER SUPPLY (M1068A3 ONLY) — Continued
0009 00
T
1.
Remove jumper cable (1) from terminal J1 (2) on power supply
PS2 (3) and terminal J1 (4) on power supply PS1 (5).
2.
Measure resistance between pins 9 (6) of jumper cable (1).
3.
Does multimeter read 0 ohms?
TN
1.
Replace jumper cable (WP 0090 00).
2.
Verify no faults found.
000900-2
Change 4


Back to Top