TM-9-2350-277-34

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

  TM-9-2350-277-34 - Page 81 of 871

TM 9-2350-277-34
VEHICLE WILL NOT ACCEPT EXTERNAL AC POWER (M1068A3 ONLY) — Continued
0008 00
18Y
NOTE
Use wiring diagram page 0018 00-14.
1.
Measure resistance between reversing contactor RC1-FWD
terminal 51 (1) and terminal 52 (2).
2.
Does multimeter read 0 ohms?
18YN
1.
Replace reversing contactor RC1
(WP 0093 00).
2.
Raise faceplate (3) and secure
with ten new lockwashers (4)
and screws (5).
3.
Verify no faults found.
19Y
1.
Raise faceplate (3) and secure with ten new lockwashers
(4) and screws (5).
2.
Verify no faults found.
0008 00-20
Change 4


Back to Top