3-3 TROUBLESHOOTING CHART — CONTINUED
d. STARTER MOTOR CIRCUIT (M109A4/M109A5) —
(1) ENGINE DOES NOT CRANK; ALL ELECTRICAL
CONTINUED
ACCESSORIES OPERATE — CONTINUED
CONTINUED FROM STEP Q
1.
2.
3.
4.
5.
Reconnect lead 10 to output side of
circuit breaker.
Disconnect lead 10 from input side of
circuit breaker.
Place red lead of multimeter in lead 10
and black lead to ground.
Turn MASTER switch ON and check for
voltage.
Turn MASTER switch OFF.
Is voltage present?
Replace circuit breaker (para
8-34).
1. Reconnect lead 10 to input side of
circuit breaker.
2. Disconnect master relay-to-driver’s bulkhead
lead assembly from driver’s bulkhead.
3. Place red lead of multimeter in lead 82
and black lead to ground.
4. Turn MASTER switch ON and check for
voltage.
5. Turn MASTER switch OFF.
Is voltage present?
Repair or replace lead 10 of power
lead wiring harness (para 8-56).
3-50
Repair or replace lead 82 of master
relay-to-driver's bulkhead lead
assembly (para 8-82).