CONTINUED FROM STEP A
I
#
B
1. Place red lead of multimeter in GND lead
connector of override switch and black lead
to ground.
2. Check for continuity.
I
Is continuity present?
I
Replace combat override switch
ground lead (para 8-89).
c
1. With MASTER switch ON and fuel shutoff
handle pulled out, crank starter until it
automatically shuts off.
2. Turn MASTER switch OFF.
3. Disconnect bulkhead-to-override switch
lead assembly from driver’s bulkhead.
4. Place a jumper wire on lead 14C and other
end to ground.
5. Turn MASTER switch ON, push STARTER
switch and check for voltage.
I
6. Turn MASTER switch OFF.
I
Is voltage present?
1
Repair or replace lead 14C of bulkhead-
to-override switch lead assembly (para
8-88).
CONTINUED ON NEXT PAGE
3-53
TM9-2350-311-20-1