TM 9-2350-311-20-1
3-3 TROUBLESHOOTING CHART — CONTINUED
x.
INSTRUMENT PANEL/PORTABLE INSTRUMENT
(2) ALL INSTRUMENT PANEL LIGHTS FAIL TO
PANEL LIGHT CIRCUIT — CONTINUED
OPERATE
.
General mechanic’s tool kit (item 64, Appx H)
Portable instrument panel cover removed (para 8-17)
Multimeters (item 36, Appx H)
Driver’s instrument panel released (para 8-17)
TA-1 probe-kit (item 43, Appx H)
A
1. Disconnect bulkhead-to-driver’s instrument
panel wiring harness from light switch.
3. Place a jumper wire from socket F (lead 15)
to socket B (lead 40).
4. Turn MASTER and instrument panel light
switches ON and check all instrument panel
lights for operation.
5. Turn MASTER and instrument panel light
switches OFF.
Do all panel lights operate?
I
Replace light switch (para 8-1 7).
I
CONTINUED ON NEXT PAGE
3-27 8