TM 9-2350-311-20-1
CONTINUED FROM STEP A
1.
-
2.
3.
4.
5.
6.
7.
8.
Reconnect accessory control box-to-heater/
blower wiring harness to personnel heater.
Disconnect battery ground leads.
Disconnect accessory control box-to-heater/
blower wiring harness from accessory control
box.
Place a jumper wire from pin A to socket A
(lead 400).
Place red lead of multimeters in socket E (lead
405) and black lead to ground.
Reconnect battery ground leads.
Turn MASTER switch ON, HEAT
SELECTOR switch to LOW and check for
voltage.
Turn MASTER and HEAT SELECTOR
switches OFF.
is voltage present?
I
Go to step D.
I
1. Disconnect battery ground leads.
2. Place red lead of multimeters on pin A (lead
400) and black lead to ground.
3. Reconnect battery ground leads.
4. Turn MASTER switch ON and check for
voltage.
5. Turn MASTER switch OFF.
Is voltage present?
Troubleshoot master relay circuit
I
Repair or replace lead 400 of accessory
control box wiring harness (para 8-53).
3-287
(para 3-3b).