TM-9-2350-311-20-1

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL FOR HULL, POWERPLANT, DRIVE CONTROLS, TRACKS, SUSPENSION, AND ASSOCIATED COMPONENTS

AUGUST 1994

  TM-9-2350-311-20-1 - Page 391 of 1275

TM 9-2350-311-20-1
CONTINUED FROM STEP I
J
1. Repair or replace both leads 402 of
accessory control box wiring harness (para
8-53).
2. Reassemble and install accessory control
box (para 8-20).
3. Turn MASTER switch ON, HEAT
SELECTOR switch to LOW and check
personnel heater for operation.
4. Turn MASTER and HEAT SELECTOR
switches OFF.
If personnel heater still does not operate, replace
personnel heater (para 11-20).
CONTINUED FROM STEP D
1.
2.
3.
4.
Reconnect accessory control box to heater/
blower wiring harness to accessory control
box.
Disconnect lead 402A from personnel heater
fuel pump.
Place red lead of multimeters in lead 402A and
black lead to ground.
Turn MASTER switch ON, HEAT SELECTOR
switch to LOW and check for voltage.
5. Turn MASTER and HEAT SELECTOR
switches OFF.
Is voltage present?
Repair or replace lead 402 of
accessory control box-to-heater/blower
wiring harness (para 8-52).
Replace personnel heater fuel pump
(para 11 -23).
I
NOTE
If personnel heater still does not operate, replace
personnel heater (para 11-20).
END OF TASK
3-291


Back to Top