TM 9-2350-311-20-1
CONTINUED FROM STEP E
F
1. With multimeters disconnected and socket B
(lead 159A) grounded, place VENTILATOR
BLOWER switch in opposite position of
where voltage was obtained in steps D and E.
2. Place red lead of multimeters in socket C (lead
159B) and black lead in socket A (lead 159C).
3. Turn MASTER switch ON and check for
voltage.
4. Turn MASTER switch OFF.
Is voltage present?
Repair or replace leads 159A, 159B and/
or 159C accessory control box ventilator
blower switch lead (para 8-67).
CONTINUED FROM STEP E
G
1. Reconnect accessory control box-to-heater/
blower wiring harness to accessory control
box.
2. Disconnect lead 10 from accessory control
box.
3. Place red lead of multimeter in lead 10 and
black lead to ground.
4. Turn MASTER switch ON and check for
voltage.
5. Turn MASTER switch OFF.
Is voltage present?
Troubleshoot master relay circuit
(para 3-3b).
CONTINUED ON NEXT PAGE
3-299


Back to Top