TM 9-2350-311 -20-1
3-3 TROUBLESHOOTING CHART — CONTINUED
ab. BILGE PUMP CIRCUIT — CONTINUED
CONTINUED FROM STEP E
I
I
F
1. Reconnect lead 452B to bilge pump circuit
breaker output.
2.
Disconnect lead 452A from bilge pump circuit
breaker input.
3. Place red lead of multimeter in lead 452A and
black lead to ground.
4. Turn MASTER switch ON and check for
voltage.
5. Turn MASTER switch OFF.
Is voltage present?
I
Repair or replace lead 452A of engine
lead assembly (para 8-81, M109A2/
M109A3; 8-82, M109A4/M109A5).
1
Replace circuit breaker (para 8-20).
BILGE PUMP FAILS TO OPERATE — CONTINUED
disconnect bracket-to-driver's bulkhead
3-308