TM 9-2350-311-20-1
H
G
1
2.
3.
4.
5.
Reconnect engine disconnect bracket-to-
bulkhead wiring harness to bilge pump relay.
Disconnect lead 450 from BILGE PUMP
switch output.
Place red lead of multimeter in BILGE PUMP
switch output and black lead to ground.
Turn MASTER and BILGE PUMP switches
ON.
Turn MASTER and BILGE PUMP switches
OFF.
Is voltage present?
L
#
I
. .
Go to step K.
I
CONTINUED FROM STEP D
1.
2.
3.
4.
5.
Reconnect lead 450 to BILGE PUMP switch
output.
Disconnect lead 450 to BILGE PUMP switch
input.
Place red lead of multimeter in lead 450 and
black lead to ground.
Turn MASTER switch ON and check for
voltage.
Turn MASTER switch OFF.
1
I Is voltage present?
Replace BILGE PUMP switch
(para 8-17).