TM9-2350-311-20-1
CONTINUED FROM STEP I
I
I
J
1. Reconnect lead 159 to circuit breaker output.
2. Disconnect lead 159 from VENTILATOR
BLOWER switch.
3. Place red lead of multimeter in lead 159 and
black lead to ground.
4. Turn MASTER switch ON and check for
voltage.
5. Turn MASTER switch OFF.
Is voltage present?
I
I
Repair or replace lead 159 of accessory
control box ventilator switch-to-circuit
r
Replace VENTILATOR BLOWER
switch (para 8-20).
END OF TASK