TM 9-2350-311 -20-1
3-3 TROUBLESHOOTING CHART —
CONTINUED
aa. PERSONNEL VENTILATION BLOWER CIRCUIT —
PERSONNEL VENTILATION BLOWER FAILS TO
CONTINUED
OPERATE — CONTINUED
CONTINUED FROM STEP G
H
1. Reconnect lead 10 to accessory control b
OX
.
2. Remove accessory control box cover (para 8-
20).
2. Disconnect lead 10A from circuit breaker
input.
3. Place red lead of multimeters in lead 10 and
black lead to ground.
4. Turn MASTER switch ON and check for
voltage.
5. Turn MASTER switch OFF.
I Is voltage Present?
Repair or replace lead 10/10A of
accessory control box wiring
harness (para 8-53).
1. Reconnect lead 10A to circuit breaker input.
2. Disconnect lead 159 from circuit breaker
output.
3. Place red lead of multimeters in circuit breaker
output and black lead to ground.
4. Turn MASTER switch ON and check for
voltage.
5. Turn MASTER switch OFF.
Is voltage present?
Replace circuit breaker (para 8-20).
CONTINUED ON NEXT PAGE
3-300