TM 9-2350-311-20-1
d. Installation
Ensure MASTER switch is OFF when working on hull electrical system to avoid
electrical shocks and bums.
NOTE
On vehicles with engine model 7083-7396, connectors 14, 15, and 16 are part of
connector 22 and are used for the flame heater system. On vehicles with engine
model 7083-7391, connectors 14, 15, and 16 are part of connector 22 and are
used for the glow plug controller system.
Access to wires 10 thru 12 will be through driver's compartment.
1 Install powerplant wiring harness.
2 install two clamps (29), two screws (28), two clamps (27), and two screws (26).
3 Install two leads (13 and 9) at starter solenoid (25). Install two flat washers (24) and two nuts (23).
4 Connect 11 electrical connectors (1 thru 8 and 10 thru 12).
5
Connect five electrica
l connectors (18 thru 22).
NOTE
FOLLOW-ON MAINTENANCE:
Close transmission access doors (para 11 -7)
Install engine access cover (para 11-5)
Connect batteries (para 8-28)
Close air intake grille (para 11 -8)
8-107
WARNIN G